Website navigation

Product Display

Position:Home > Products > CVD/PECVD System > Low Vacuum System >
Single-zone Mini Chemical Vapor Deposition CVD System With Float Flow Meters
Single-zone Mini Chemical Vapor Deposition CVD System With Float Flow Meters

Single-zone Mini Chemical Vapor Deposition CVD System With Float Flow Meters

Model:KJ-T1200-S5020-F

Description:

1200℃ Mini Gas-Mixing CVD system comprise of a mini Tube Furnace, a two-channel gas-mixing unit with float flow meters, a vacuum pump unit of 10Pa.

Products
Detailed
Range of Application:
It’s mainly used for sintering and reduction in atmospheres, also in research of graphene, materials for lithium battery, annealing of crystal, luminescent materials and so on.
 
Parameters:

Product

Single-zone Mini Chemical Vapor Deposition CVD System With Float Flow Meters

Model

KJ-T1200-S5020-F

Insulation layer

Alumina ceramic fiber

Tube

Quartz, Φ50*800mm.

Heating Zone

200mm

Top Temperature

1200℃

Working Temperature

1100℃

Temperature Control Accuracy

+/- 1℃

Temperature Control

Intellectual 30-segment programmable controller with over-temperature protection

Sealing

Customizable flanges with gas valves, pressure gauge and so on.

Gas Supplying Unit

Adjustable float flow meters

No need for electricity

Vacuum Pump Unit

10pa Vacuum pump with dust filter

Digital pressure gauge

Heating Rate

0-20℃/min (Suggestion: 0-10℃/min)

Heating Element

0Cr27Al7Mo2 resistance wire

Power supply

AC220V, 50Hz (Customizable)

Power

2kW

Temperature Sensor

K-type Thermocouple

Accessories

Crucibles, Crucible Tongs, Gloves, Insulation blocks.

Notes

Pressure higher than 1.02Mpa will break the tube.

Since the pressure in the gas cylinder is high, a converter is necessary. The measurement range of our converter is 0.01mpa-0.1mpa, will ensure a safe gas supply.

No vacuum condition is allowed when the temperature is higher than 1000℃.

Please keep the gas flow lower than 200sccm when the temperature is high to lower the impact of cold air to the hot tube.

If you have to keep the valves on the two ends of the tube closed at the same time, please watch the pressure gauge and open the valves once the pressure is higher than 1.02Mpa to avoid any tube breakage.

Certificate

CE, ISO.

After-sale Service

1-year warranty and life-time technical support

 


MESSAGE

Contact Information

E-mail:
web@kejiafurnace.com
Address:
No.18 Hongye Road, Hi-tech zone , Zhengzhou, China, 450000
QQ tel Email WhatApp FaceBook

Tel Number

181-3719-5600

Email

web@kejiafurnace.com

WhatsApp

+86/18037178440

FaceBook

Zhengzhou/Kejia